Operation & Maintenance of Mechanical/HVAC infrastructures within Data Center (Chiller system, TES system, Pump system, Plumbing system, FWUs, IRUs, DX units, VRF/VRVs, Fire Pump/Sprinkler system, diesel generators etc) and all associated system to ensure integrity, high availability, maximum performance, and efficiency. Prepare SOPs for all mechanical services and manage specialist sub-contractors.
KEY RESPONSIBILITIES:
Organise and prepare preventive maintenance shutdown works for mechanical equipment and systems including potable water, fire sprinkler, diesel generator, chiller systems, AHU systems, FCU\'s, split AC.
Organise and prepare mechanical system repair/modification shutdown works.
Carries out routine checks and logs/provides reports of the status of mechanical infrastructure.
Prepare requisitions for materials required for maintenance and repair.
Fault finding on electromechanical systems within the facility.
Carry out routine testing to determine condition of mechanical systems and recommend/implement corrective actions.
Manage hard service subcontractors - ensure services on time and high quality.
Manage store operation - oversee stores supervisor and cleaning supervisor.
Maintain 100% uptime for \'operational\' mechanical services.
Overhaul and repair pump sets including bearing and mechanical seal change.
Input details of maint and repair into the CAFM systems.
Organise attendance of subcontract labour and Control subcontractors when on site
Operate within a safe system of work for mechanical systems, issue PTW, LOTO etc.
Ensure all works are carried in line with Company Procedures and Policies, Health and Safety, Control of Hazardous materials, in line with COSHH regulations and PPE.
SKILLS REQUIRED:
Ability to work independently in a timely manner, making sure job is done correctly the first time.
Monitor and measure performance of mechanical systems, provide reports, energy saving input, RCM assessment for mechanical systems.
Use of flow meters, anemometers, hygrometers to determine performance of HVAC systems/room conditions, psychometry, duct air systems balance, water systems balance.
Ability to read, write and speak in English.
Proficiency in Microsoft Word, Excel and Outlook.
Good analytical skills and attention to detail with ability to read and interpret blueprints, plans, and manuals.
QUALIFICATIONS:
Bachelor of Engineering in Mechanical.
3+ years of experience in Data Center Facilities or equivalent critical facilities maintenance.
7+ years of total Experience in Operation & Maintenance.
OTHER REQUIREMENTS:
ATD or similar Datacenter certification will be an added advantage.